With JohnsonFoils' patented DUR-LOC® hivac cover design, individual elements can be removed while the cover and unit stay in place on the paper machine.

Features

  • The unique patented DUR-LOC®attaching device securely locks individual elements to a base grid, yet is easily disengaged to remove the element
  • Each DUR-LOC®cover element can be replaced without removing the cover of the unit
  • DUR-LOC® substructure with 316SS machine direction supports can be designed to accommodate pressure drops up to or in excess of 20" Hg (67.54 kPa)
  • DUR-LOC®covers for high vacuum units are manufactured in flat, curved or special profile designs to suit new or existing installations
  • Rigid cover assemblies are bolted directly to new hivac units or designed to accommodate existing hivac cover configurations
  • Uninterrupted slots remove water evenly
  • Available in standard slot widths of 1" (25 mm), 3/4" (19 mm), 5/8" (16 mm) and 1/2" (13 mm); numbers of slots and widths are custom selected for each application
  • Elements can be supplied in a wide variety of ceramic materials carefully chosen and tested for paper machine operation
  • Elements are manufactured with chamfered or doctoring profiles to suit the application on the machine
  • Custom shapes can be designed
  • The DUR-LOC® element's FRP sub-base has a coefficient of thermal expansion consistent with the ceramic used
  • Individually adjustable end deckle pieces seal at wire level
  • Special high temperature deckles are available for service under steam hoods
  • Lubri-deckles are available to provide extra lubrication at fabric edges
  • Johnson Foils can repair damaged elements

Standard Available Hivac Ceramics

  • Premium Aluminum Oxide (PAO) 99.5% Pure
  • Silicon Nitride (SiN)
  • Silicon Carbide (SiClp)
  • Zirconia (ZIR)

 

 

©2008 AstenJohnson. All Rights Reserved.